GE Biacore 3000 SPR Biomolecular Interaction Analysis System

sku: BB3362468
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : EC
$2,500.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Biacore
  • Hertz 50Hz/60Hz
  • Model BIACORE 3000
  • Serial 33-1151229-CH3764
  • Weight 600
  • Voltage 120V
  • Working Not Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 24×70×31 in
  • Shipping Type Freight
  • Item Condition Pre-owned

**This unit is sold As/is missing components.Could not test unit to specifications 

Systems from Cytiva have a reputation for quality and reliability. Cytiva now makes it possible to acquire these high-quality systems.

  • Recover and characterize interaction partners using MALDI-MS interface.
  • Elucidate disease mechanisms by characterizing native or recombinant protein interactions.
  • Define potential drug targets or diagnostic markers.

Biacore 3000 processing unit is an established, label-free system for detailed studies of biomolecular interactions. The system delivers comprehensive characterization of the interaction, answers questions about the rate constants, affinity, specificity, and determines the active concentration of components. The unique ability to recover and transfer interaction partners directly to MALDI targets for identification and further characterization makes the system highly applicable to fast identification of unknown interactants.

Analysis temperature 4 - 40°C 
Application Kinetic/affinity characterizationkinetic/affinity screening and profilingconcentration measurement LMW interaction analysisThermodynamic characterization and sample recovery for MS 
Automation Automated sample loading and injection 
Baseline drift <0.3 RU/min 
Baseline noise <0.3 RU (RMS) 
Capacity Up to 2 x 96 samples 
Depth 350 mm 
Detection Spots
Detection technology Surface plasmon resonance (SPR) biosensor 
Flow rate < 100 μl/min, through flow cell, steps of 1 μl 
Height 610 mm 
In-line reference subtraction Yes (flow cell 2 to 1, 3 to 1, 4 to 1, 4 to 3) 
Includes Biacore 3000 processing unit, control and evaluation software, handbooks 
Injection volume 5-750 µl 
Molecular weight detection >180 Da 
Number of flow cells 4 (Used individually, in series or as 2 pairs) 
Power consumption 580 VA 
Sample concentration min. 10 x 10-12
Sample volume min. Injected volume + 20 to 80 μl, depending on application 
Voltage 100-120 V; 220-240 V 
Volume 0.03 µl 
Weight 50 kg
Width 760 mm
Pack size

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”