Keyence One-Shot VR Series Wide-Area 3D Measurement System VR-5200 w/ Controller
- Make Keyence
- Hertz 50Hz/60Hz
- Model VR-5000 & VR-5200
- Serial 3C120013 & 1C120038
- Weight 75
- Voltage 120V/220V
- Working Working
- Includes Power Cord
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 23×22×23 in
- Shipping Type FedEx Ground
- Item Condition Pre-owned
Keyence One-Shot VR Series Wide-Area 3D Measurement System VR-5200 w/ Controller
***This unit was tested as far as we could. We don't have the software to fully test this instrument. Buyer can expect everything pictured with 30-day warranty. See photos for details.
includes:
- VR-5200 Wide-Area 3D Measurement System Head
- VR-5000 Wide-Area 3D Measurement System Controller
Form, Contour, and Roughness Measurements in as Little as 1 Second
- 3D imaging & measurement with a single device
- 4× faster than conventional systems
- High-speed data acquisition and analysis
- Scan and measure a surface in as little as 1 second
Industry's first
Automatic operation with place-and-measure capability
- Automatically identifies and adjusts measurement settings based on object size
Contact-based measurement
Typical measurement systems only provide measurement data on the areas that they are able to contact with a probe tip. Measuring specific locations by simply eye-balling where to put the probe makes the results unreliable. Data is limited to points or lines.
Non-contact surface measurement
The VR Series Wide-Area 3D Measurement System quickly scans an entire surface for reliable measurement of any point on the object. A dense data set is captured over an entire area.
- Measure 3D surface changes over a large area
- Measure complex shapes and roughness
- Measurement area up to 200 × 100 × 50 mm 7.87" × 3.94" × 1.97"
5× the measurable height range of conventional systems
Measurement is possible for targets up to 50 mm 1.97" tall —five times that of conventional systems. Measurement can be done on a wide range of targets including screws, electronic components, non-flat castings, and assembled products. To ensure high measurement accuracy, the stage is equipped with a high-precision linear scale and a proprietary sensor. By eliminating influence from various environmental factors such as temperature changes or tilting due to load weight, the VR series ensures constant measurement quality regardless of the user.
Measure multiple targets simultaneously
With a 200 × 100 mm 7.87" × 3.94" measurement range, multiple objects can be placed on the stage and measured at the same time. The VR Series can also be used to measure a tray of parts, as well as equidistant pins or holes. Automating both the data acquisition and analysis in this way dramatically improves productivity.
Manufacturer's Specifications:
Model |
VR-5200 |
|||
Type |
Head |
|||
Light sources |
Observation light source |
LED ring light (red, blue, green) |
||
Measurement light source |
White LED |
|||
Controller |
VR-5000 |
|||
Field-of-view |
Low magnification (wide field of view) |
Magnification on a 15" monitor 12× |
Horizontal |
24.0 mm 0.94" |
Vertical |
18.0 mm 0.71" |
|||
Magnification on a 15" monitor 25× |
Horizontal |
12.0 mm 0.47" |
||
Vertical |
9.0 mm 0.35" |
|||
Magnification on a 15" monitor 38× |
Horizontal |
8.0 mm 0.31" |
||
Vertical |
6.0 mm 0.24" |
|||
Magnification on a 15" monitor 50× |
Horizontal |
|||
Vertical |
4.5 mm 0.18" |
|||
High magnification (high resolution) |
Magnification on a 15" monitor 40× |
Horizontal |
7.6 mm 0.30" |
|
Vertical |
5.7 mm 0.22" |
|||
Magnification on a 15" monitor 80× |
Horizontal |
3.8 mm 0.15" |
||
Vertical |
2.9 mm 0.11" |
|||
Magnification on a 15" monitor 120× |
Horizontal |
2.5 mm 0.10" |
||
Vertical |
1.9 mm 0.07" |
|||
Magnification on a 15" monitor 160× |
Horizontal |
|||
Vertical |
1.4 mm 0.06" |
|||
Zoom |
1× to 4× |
|||
Height measurement |
Display resolution |
0.1 µm |
||
Height measurementrange |
Without Z stitching |
Low magnification (wide field of view) : 10 mm 0.39" |
||
With Z stitching |
Low magnification (wide field of view) : 50 mm 1.97" |
|||
Repeatability (σ) |
Without Z stitching |
0.4 µm*1 |
||
With Z stitching |
1.0 µm*1 |
|||
Measurement accuracy |
Without Z stitching |
±2.5 µm*1 |
||
With Z stitching |
±4.0 µm*1 |
|||
Width measurement |
Repeatability (σ) |
Low magnification (wide field of view) : 1 µm |
||
Measurement accuracy |
Low magnification (wide field of view) : ±5 µm |
|||
Stitching function |
Fully-automated measurement (XY automatic control + Z automatic control)*2 |
|||
XY measurable range |
206 x 104 mm 8.11" x 4.09"*2 |
|||
Stage |
XY stroke |
184 x 88 mm 7.24" x 3.46" (motorized) |
||
Z stroke |
73 mm 2.87" (motorized) |
|||
Load capacity |
4.5 kg |
|||
Working distance |
75 mm 2.95" |
|||
Image receiving element |
4 megapixel monochrome CMOS |
|||
Transmitter lens |
Double-telecentric lens x 2 |
|||
Receiver lens |
Double-telecentric lens |
|||
Data processing |
Dedicated PC specified by KEYENCE (OS: Windows 10 Pro) |
|||
Power supply |
Power voltage |
100 to 240 VAC, 50/60 Hz |
||
Power consumption |
200 VA max. |
|||
Environmental resistance |
Ambient temperature |
+15 to 30 °C 59 to 86 °F |
||
Relative humidity |
20 to 80 % RH (no condensation) |
|||
Weight |
Approx. 28 kg*3 |
Model |
VR-5000 |
|||
Type |
Controller |
|||
Light sources |
Observation light source |
LED ring light (red, blue, green) |
||
Measurement light source |
White LED |
|||
Head |
VR-5200, VR-5100 |
|||
Field-of-view |
Low magnification (wide field of view) |
Magnification on a 15" monitor 12× |
Horizontal |
24.0 mm 0.94" |
Vertical |
18.0 mm 0.71" |
|||
Magnification on a 15" monitor 25× |
Horizontal |
12.0 mm 0.47" |
||
Vertical |
9.0 mm 0.35" |
|||
Magnification on a 15" monitor 38× |
Horizontal |
8.0 mm 0.31" |
||
Vertical |
6.0 mm 0.24" |
|||
Magnification on a 15" monitor 50× |
Horizontal |
|||
Vertical |
4.5 mm 0.18" |
|||
High magnification (high resolution) |
Magnification on a 15" monitor 40× |
Horizontal |
7.6 mm 0.30" |
|
Vertical |
5.7 mm 0.22" |
|||
Magnification on a 15" monitor 80× |
Horizontal |
3.8 mm 0.15" |
||
Vertical |
2.9 mm 0.11" |
|||
Magnification on a 15" monitor 120× |
Horizontal |
2.5 mm 0.10" |
||
Vertical |
1.9 mm 0.07" |
|||
Magnification on a 15" monitor 160× |
Horizontal |
|||
Vertical |
1.4 mm 0.06" |
|||
Zoom |
1× to 4× |
|||
Height measurement |
Display resolution |
0.1 µm |
||
Height measurementrange |
Without Z stitching |
Low magnification (wide field of view) : 10 mm 0.39" |
||
With Z stitching |
Low magnification (wide field of view) : 50 mm 1.97" |
|||
Repeatability (σ) |
Without Z stitching |
0.4 µm*1 |
||
With Z stitching |
1.0 µm*1 |
|||
Measurement accuracy |
Without Z stitching |
±2.5 µm*1 |
||
With Z stitching |
±4.0 µm*1 |
|||
Width measurement |
Repeatability (σ) |
Low magnification (wide field of view) : 1 µm |
||
Measurement accuracy |
Low magnification (wide field of view) : ±5 µm |
|||
Stitching function |
VR-5200: Fully-automated measurement (XY automatic control + Z automatic control) , Automatic mapping creation, Automatic area setting |
|||
XY measurable range |
VR-5200: 206 x 104 mm 8.11" x 4.09" |
|||
Stage |
XY stroke |
VR-5200: 184 x 88 mm 7.24" x 3.46" (motorized) |
||
Z stroke |
73 mm 2.87" (motorized) |
|||
Load capacity |
4.5 kg |
|||
Working distance |
75 mm 2.95" |
|||
Image receiving element |
4 megapixel monochrome CMOS |
|||
Transmitter lens |
Double-telecentric lens x 2 |
|||
Receiver lens |
Double-telecentric lens |
|||
Data processing |
Dedicated PC specified by KEYENCE (OS: Windows 10 Pro) |
|||
Power supply |
Power voltage |
100 to 240 VAC, 50/60 Hz |
||
Power consumption |
200 VA max. |
|||
Environmental resistance |
Ambient temperature |
+15 to 30 °C 59 to 86 °F |
||
Relative humidity |
20 to 80 % RH (no condensation) |
|||
Weight |
Approx. 4 kg |
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”