Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is
Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is

Agilent G1120A Multi Cell Transport for 8453 UV-vi CLEARANCE! As-Is

sku: 3370902
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$229.00$750.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Agilent
  • Model G1120A
  • Serial CN22501477
  • Weight 10
  • Working Working
  • Warranty AS-IS
  • Dimensions 8×20×11 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

Agilent G1120A Multi Cell Transport for 8453 UV-visible Spectrophotometer

**This item was tested to specifications. G1120A has slight wear from normal use. Buyer can expect the same item pictured and 30-day warranty. See photos for details. 

The eight-position multicell transport (G1120A) is an accessory for the Agilent 8453 UV-visible spectrophotometer. It is a multiple-sample holder with multiple-position capability. The multicell transport cell holder holds eight cells in a rack which can be held at a constant temperature with water circulated from a thermostatic bath (provided by the user and not supplied by Agilent Technologies)

The holder is attached to the multicell transport base which contains a stepper motor to move the designated cell into the optical path. A water-driven magnetic stirrer can be fitted under the holder in one of two positions—either under the cell in the optical path or under the cell to the left
of the cell in the optical path. The multicell transport can be controlled by any Agilent Technologies
UV-visible operating software, having revision A.05.xx or higher, through the accessory interface of the spectrophotometer.

Manufacturer's Specifications:

  • Time to move between adjacent cell positions: < 1 second
  • Position repeatability: ± 0.1 mm Linear position error in moving  to a cell position within 1 hour
  • Step resolution: 0.060 mm
  • Temperature range for thermostatting (cell holder only): 5–90 °C
  • Temperature difference between any two cell positions: 0.3 °C With a water bath at 37 °C