Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is

Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is

sku: 3370180
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$4,499.00$15,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Agilent
  • Hertz 50Hz/60Hz
  • Model G1888A
  • Serial IT00710007
  • Weight 142
  • Voltage 120V/220V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 29×23×30 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

Agilent G1888A Network Headspace Sampler

The Agilent G1888 Headspace Sampler lets you automatically introduce volatile compounds from virtually any sample matrix directly into a GC or GC/MSD system. It features an inert sample pathway for superior chemical performance without analyte
degradation or loss. And its high sample capacity and increased sensitivity ensure excellent performance for a wide range of analysis.

**This unit has been tested for basic functionality. See photos for details. Everything pictured included. 

 

Built-in performance and reliability

From sampling… to detection… to data analysis and reporting… Whether your application is pharmaceutical, food safety, environmental, or forensic… The G1888 is a fully integrated system that gives you unsurpassed confidence in your results.

 

Features:

  • 70-sample tray and 12 positions in the heating oven allow unattended overnight operation for many applications
  • Automated constant heating time is employed with optimized sample overlapping for maximum sample throughput in the minimum amount of time
  • Deactivated sampling path, from sampling needle to transfer line, is standard so coupling with an inert 7890A or 6890N Volatiles Interface achieves complete chromatographic system inertness
  • Controlled temperature range from 40 degrees C to 230 degrees C makes it possible to analyze semi-volatiles at temperatures over 200 degrees C, as well as traditional applications for low boiling point analytes
  • Heated zones can be turned off, which allows analyses at ambient conditions for biological or extremely thermally sensitive analytes
  • Incorporates two modes of multiple headspace extraction (MHE) in addition to routine single extraction (one sampling per vial)
  • Multi-puncture extraction with up to 100 extractions per vial is possible for the analysis of samples in unusual matrices
  • A 'concentration mode' of MHE allows multiple extractions from a vial to be made, followed by the start of the GC run after the last extraction
  • Includes several convenient testing and troubleshooting features, including a set of four pre-stored chemical test methods, a semi-automated leak test, and a detailed power-on self-test
  • Instrument control can be achieved using the GC ChemStation, MSD Productivity ChemStation and MSD Security ChemStation, or Cerity NDS for Pharmaceutical QA/QC
  • Instrument control is integrated with drop-down menus for ease of method setup. The existing sequence table is used to set up analyses, maintaining optimized sample overlap and constant heating time.
  • An event log function tracks every headspace sampler operation and reports any temperature and pressure deviation compared to the set point in compliance with 21 CFR Part 11
  • Built-in keypad control enables compatibility with all GCs

 

Manufacturers Specifications:

Sample Capacity

  • Holds 70 vials in tray. Twelve position oven for optimized sample overlapping constant time heating.

Sample Vials

  • Standard crimp top or screw cap vials, 20 mL, 10 mL. No adaptor required for 10-mL sample vials.

Mode of Operation

  • Shaking with choice of off, low, or high.
  • Constant heating time (CHT) mode for each sample. Overlapping up to 12 vials for maximized sample throughput
  • Multiple headspace extraction (MHE) mode with up to 100 extractions per vial for method development and validation or for analysis of sample in unusual matrices
  • Multiple headspace extraction concentration (MHC) mode, with up to 10 extractions from 1 vial made followed by one GC start after the last extraction to increase sensitivity

Zone Temperature

  • All temperature zones can be set off
    Oven heating: 40 °C to 230 °C in 1 °C increments; 0.5–999 min in 0.1 min increments
  • Loop/Valve: 45 °C to 250 °C
  • Transfer line: 50 °C to 250 °C

Sample Pathway

Inert deactivated path from sample needle to transfer line. Transfer line length: 85 cm. Sample loop: 1 mL (standard), 3 mL (option)

Pneumatic Control

  • In-unit switch connection between: Built-in manual pneumatics (pressure regulator and flow controller) and GC built-in electronic pneumatic control (EPC)

  • Interfacing with GC
    Volatile inlet (VI) or other standard GC inlet

Communication

  • LAN; RS-232; Remote start/stop

System Control

  • Control and monitoring by full function control keypad and built-in multiline display. Features:
    • Parameter set up
    • Store up to four user defined headspace methods (there are also five preset methods)
    • Detailed power-on self test
    • Built-in leak test routine
    • Update firmware via LAN or RS-232
    • Monitor set and actual values, as well as, operation status

Environmental Conditions

  • Operation: 10 °C to 35 °C
  • Storage: –40 °C to 70 °C
  • Humidity: 5% to 95%
  • Line voltage: 100–240 V ±10%
  • Power required: 750 VA maximum