Thermo Scientific Dionex Water Purification System IC Pure As Is (needs parts)
- Make Thermo
- Hertz 50Hz/60Hz
- Model IC Pure
- Serial 2302312001787
- Weight 100
- Voltage 120V
- Working Working
- Includes Power Cord|User Manuals
- Warranty AS-IS
- Dimensions 32×23×25 in
- Shipping Type Freight
- Item Condition Pre-owned
- Manufacturing Date 2312
Thermo Scientific Dionex Water Purification System IC Pure As IS or for Parts
**This unit has been tested as far as we could. Dionex IC Pure is not able to reach the 18.2 MOhm/cm. The value is not increasing more than 10 MOhm/cm. Has slight cosmetic blemishes from normal use. See photos for further details.
Unit will need new filters.
- Provides ultrapure water for one or two RFIC systems
- Point-of-use system designed to simplify operation
- 3 psi pressurized ultrapure water for electrolytic eluent generation
- 30 psi pressurized ultrapure water for electrolytic suppressors operating in external water mode
- Provides large reservoir of pretreated or tap water for ultrapure water production
- Never needs refilling – the 20L tank is automatically refilled when levels are low
- Displays key operating conditions
- Provides system set up and control at the instrument
- Contains high quality resin for consistent purity and long cartridge life
- Aquastop quick connections for fast replacement
- System footprint measures 55cm (21.65 in) H x 30.6cm (12.05 in) W x 38.5cm (15.16 in) D
- Optional wall mounting bracket for additional space saving
- Easy addition of pretreated or tap water
- Long refill requires less operator time and attention
- Direct readout of water quality
- Warns when consumable change is needed
- Alarms when feed water quality is compromised
Specifications
Source | potable tap water | pretreated water (ASTM Type II) |
Silt density index(SDI) | < 3 | -- (not applicable) |
Conductivity (reference temperature +25 °C) |
1200 µS/cm (0.0008 M·cm) | < 1 µS/cm or > 1 M·cm |
Free chlorine | max. 0.1 ppb (µg/L | Max. 0.05 ppb (µg/L) |
Manganese content | max. 0.05 ppm (mg/L) | -- (not applicable) |
Iron content | max. 0.05 ppm (mg/L) | -- (not applicable |
pH range | 4 - 11 | 4 - 11 |
TOC value | < 2000 ppb (µg/L) | max. 50 ppb (µg/L) |
Bacteria count | < 100 CFU/mL | < 100 CFU/mL |
Turbidity | < 1.0 NTU | < 1.0 NTU |
Carbon dioxide (CO2) |
max. 30 ppm (mg/L) | max. 30 ppm (mg/L) |
Silicate | max. 30 ppm (mg/L) | max. 3 ppm (mg/L) |
Temperature | +2 - +35 °C (35.6 to 95 °F) | +2 - +35 °C (35.6 to 95 °F) |
Pressure for automatic filling |
1.45 - 58 psi (at a pressure > 58 psi a pressure reducer must be installed upstream of the unit. |
-- (not applicable) |
Conductivity (reference temperature +25 °C) | 0.055 µS/cm |
Resistance | up to18.2 M·cm |
TOC value | max. 5 ppb (µg/L) |
RNase DNase |
< 0.003 ng/mL < 0.4 pg/uL |
Bacteria | < 0.1 CFU/mL |
Bacterial endotoxines | 0.001 EU/mL |
Particles > 0.2 µm per mL | < 1 µm/mL |
Flow rate without pretreatment cartridge at manually operated point of use (POU) |
0.6 L/min ± 0.2 L/min |
Flow rate with pretreatment cartridge at manually operated POU |
0.2 L/min + 0.2 L/min |
Feedwater conductivity | 0.16 cm-1 |
Conductivity TOC | 0.01 cm-1 |
Ultra pure water conductivity | 0.01 cm-1 |
Feedwater tubing | 8 mm (0.31 in) o.d. |
Input voltage | 100 – 240 VAC, 50 – 60 Hz, 2.0 A max |
Temperature range |
min. +2 °C, max +40 °C, 80% relative humidity, non-condensing/ Storage: min. +2 °C, max. +60 °C, 90% relative humidity, non-condensing |
Degree of pollution | 2 |
Sound pressure leve | 49 db(A) |