ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000
ORFLO Moxi Z Mini Automated Cell Counter MXZ000

ORFLO Moxi Z Mini Automated Cell Counter MXZ000

sku: 3376455
1 In Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$2,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make ORFLO
  • Hertz 50Hz/60Hz
  • Model Moxi Z
  • Serial 1108600008
  • Weight 7
  • Voltage 120V
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 15×12×10 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

ORFLO Moxi Z Mini Automated Cell Counter MXZ000

 **Unit has been tested to specifications. Has slight cosmetic blemishes from normal use. Cassettes not included. See photos for further details.

Moxi Z is the only automated cell counter that combines the Coulter Principle typically used in high-end cell counters with a patented thin-film sensor technology to allow for highly accurate (> 95%) and repeatable particle counting and sizing for a broad range of cell types – from mammalian cells to cells as small as wine yeast and more. Since today’s workflows demand accurate quality control of samples, determining cell counts precisely has a significant impact on outcomes and downstream costs.

Produce repeatable cell counts with >95% accuracy in just 8 seconds: This ultra-small instrument uses patented microfluidic thin-film cassettes that enable automatic load and measure operation. The resulting single cell volumetric measurements are completely technique-independent. It provides the ideal alternative to the tedious manual counting associated with cytometers, or the inaccurate results associated with image-based automated cell counters (typical accuracies of 75-80%).

Assess cell culture health without reagents or dyes: Moxi Z also automatically reports a unique cell health assessment index – MPI (Moxi Population Index) – without the need for reagents or dyes.MPI is a ratio of the cell population of interest relative to the entire particle distribution in that sample, factoring in dead cells that have shrunken or broken apart as well as other debris and contaminants in the sample. For monodisperse mammalian cultures this is closely correlated to the overall health of the sample.In the case of mixed cell populations, it’s provides an assessment of the relative fraction of the largest sized population in the sample. Unlike staining-based viability methods that focus on the uptake by dead cells and do not account for contaminants and other debris, MPI provides insight on the primary population of interest (based on size) and its relationship to ALL other particles in the sample.

Measure the smallest cells at very high concentrations.

Using the new Type S cassette, you can now accurately measure the smallest cells of any automated cell counter (down to 3um average diameter) at concentrations of up to 2.5e+6/ml. This means the new Type S cassette can measure Yeast (including wine yeast) and non-spherical particles down to 14 fL in volume.

  • Results in just 8 seconds
  • Ultra-small and ultra-easy to use (no manual counting, no focusing of any kind)
  •  Complete, high-resolution cell size/count histogram
  • Handles “de-aggregation” and coincidence events
  • Post-processing/analysis of count distributions with user-adjustable regions/gates
  • Assess cell health (MPI) without the need for reagents like Trypan blue

Specifications

AC Power Type 110 VAC
Applications Cell Counting | Cell Size | Cell Health
Average Cell Diameter Range 4 – 25 microns Type M|3 – 20 microns Type S
Battery Type Rechargeable 3.7 V, 4400 mAh lithium ion
Cassette Types Type M|Type S
CE Certification Yes
Cell Particle Concentration Range 3,000 – 500,000 cells/mL Type M|3,000 – 1,750,000 cells/mL Type S
Cell Types Tested HEK-293|HeLa|PC12|CD3+T|CHO-K1|Cos-7|HepG2|Hybridoma|Jurkat E6-1|K562|MCF7|Mesenchymal SC|Monocyte|Mouse ESC| NIH 3T3| PBMC (cultured)|Red Blood Cells (RBC)|L5178y| C. albicans (Yeast)| S. cerevisiae Vin 13 (Yeast)|S. cerevisiae X5 (Yeast)|Wine Yeast (natural fermentaion)|S.cerevisiae (Baker’s Yeast|Safale US-05 Yeast
Compatible Instruments MOXI Z
Data Output Formats .csv format (Orflo MoxiChart or Microsoft Excel)
Measurable Dynamic Range 4- 34 microns Type M|3 -26 microns Type S
Measurement Time 15 seconds Type S|10 seconds Type M
MPI Cell Health Ratio Yes
Number of Detection Channels Flow parameters 1
Platform No
Pre-Programmed Tests None
Sample Type Mammalian Cells|Large Yeast|Large Algae|Protozoa Type M/ Mammalian Cells|Most Yeast|Small Algae|Small Protozoa Type S
Pre-Programmed Tests None
Sample Type Mammalian Cells|Large Yeast|Large Algae|Protozoa Type M/ Mammalian Cells|Most Yeast|Small Algae|Small Protozoa Type S
Sample Volume 75 µL
Supported Connectivity USB on-the-go; PC or Mac compatible; requires Windows XP, Windows Vista, Windows 7, or Mac OS X operating system
Useable Cell Volume 34 – 20,580 fL Type M|14 – 4,200 fL Type S

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”