Bio-Tek 405TS Select Touch Microplate Washer
- Make Bio-Tek
- Hertz 50Hz/60Hz
- Model 405TSUVS
- Serial 17102416
- Weight 41
- Voltage 120V
- Working Working
- Includes Power Cord
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 24×21×17 in
- Shipping Type FedEx Ground
- Item Condition Pre-owned
- Manufacturing Date 2017-10-24
Bio-Tek 405TS Select Touch Microplate Washer
**Unit has been tested to specifications. Has slight cosmetic blemishes from normal use. See photos for further details.
The BioTek 405 TS washer has an excellent reputation in life science research for outstanding results in many applications. The 405 TS has a unique set of features designed to efficiently wash cell-based assays, microsphere-based assays, and ELISA applications. Programming and operation via the touchscreen interface is intuitive and simple. The patented Verify technology automatically checks for manifold tube blockages before a wash cycle, and Ultrasonic Advantage automatically cleans any blocked manifold tubes. These functions save time and eliminate frustration while ensuring successful results.
Features
- Self-maintaining design with an ultrasonic bath prevents clogging and failure in the plate washer. The built-in, patented Ultrasonic Advantage allows the instrument to clean build up in the manifold tube automatically, without manual intervention.
- Hands-off, self-testing Verify technology eliminates tedious manual procedures using an ultrasonic probe to check dispense and aspirate performance. Test results are automatically displayed and indicate when tubes may require additional cleaning.
- Automated magnetic and filtration bead-based assays provide flexible operation in many applications. Variable wash steps and magnet accessories for biomagnetic separation workflows ensure high bead recovery. Vacuum filtration module is also available.
- Cell-friendly design for high-quality results with angled dispense tubes, highly adjustable dispense, and aspiration rate settings for cell-based assays. The gentle flow rates and side-wall dispensing position ensure the integrity of cell monolayers.
Self-maintaining design with patented ultrasonic bath
Manifold tube clogs are the most common source of failure on plate washers. The built-in, patented Ultrasonic Advantage allows the instrument to clean build up in the manifold tube automatically, without removing it from the instrument.
Hands-off self-testing Verify technology option
The Verify technology option eliminates tedious manual procedures by using an ultrasonic probe to check dispense and aspirate performance. Test results are automatically displayed and indicate tubes that may require additional cleaning.
Automate magnetic and filtration bead-based assays
Multiplexed bead-based assays are very common, and 405 TS easily accommodates necessary wash steps. Magnet accessories for biomagnetic separation workflows, available in both flat and 4-zone ring designs, ensure high bead recovery. A vacuum filtration module is available for polystyrene bead assays.
Cell-friendly design for high quality results
A combination of angled dispense tubes and highly adjustable dispense and aspiration rate settings make 405 TS the ideal washer for cell-based assays. The gentle flow rates and side-wall dispensing position ensure the integrity of cell monolayers
Microplate Types | 96- and 384-well Low profile and standard height Solid and filter bottom (option) |
Onboard Software | Create, edit, or run multiple protocols |
Software (Computer Control) |
Agilent BioTek Liquid Handling Control (LHC2) software Agilent BioTek LHC2 Secure software enables 21 CFR Part 11 compliance (option) Agilent BioTek LHC SiLA compliant driver (option) |
Separation | Biomagnetic separation, vacuum filtration (optional) |
Shaking | Programmable up to 60 minutes Slow, medium, fast, or variable |
Soaking | Programmable up to 60 minutes |
Ultrasonic Advantage |
Yes (option) |
Verify Technology Clog Detection |
Yes (option) |
Automation | Agilent BioTek BioStack microplate stacker and third-party automation compatible Agilent BioTek BioSpa 8 automated incubator compatible Agilent BenchCel microplate handler compatible |
Manifold Types | 96-well washing: 96-tube manifold−straight dispense tubes 96- and 384-well washing: 96-tube Dual-Action manifold−20° angled dispense tubes 384-well washing (fast): 192-tube Dual-Action manifold−7° angled dispense tubes |
Volume Range | 25−3,000 µL/well (192-pin manifold) 50−3,000 µL/well (96-pin manifold) |
Wash Cycles | 1−250 |
Buffer/Reagent Selection |
Auto switching module for up to four buffers (option) |
Supply Bottle | 4 L or 10 L (optional) |
Dispense Precision | < 3% CV: 300 µL/well (96-well washing) < 4% CV: 80 µL/well (384-well washing) |
Residual Volume | ≤ 2 µL/well (96- and 384-well plates) 96-tube manifold for 96 wells; 192-tube for 384 wells |
Wash Speed | 96-wells, 300 µL/well, 3 cycles; ≤ 30 s 384-wells,100 µL/well, 3 cycles: ≤ 80 s 384-wells, 400 µL/well, 1 cycle: ≤ 20 s |
Flow Rates | High flow to low flow Optimized rates for cell assays |
Sterilization | Chemical |
Vacuum Filtration | Selectable: approximate final at 30 s: Lowest: −38 mmHg Low: −113 mmHg Medium: −200 mmHg High: −390 mmHg Highest: −506 mmHg Vacuum filtration time range: 5−999 s |
Power | 100−240 Volts AC at 50−60 Hz |
Automation Compatibility |
|
Fluid Pump Type |
|
Instrument Control |
|
Number of Reagents |
|
Processes |
|
Supported Labware |
|
Washer/Dispenser Options |
|
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”