Mettler Toledo Thornton Conductivity Sensors 58031223/413/235/014/002
- Make Mettler Toledo
- Model 58031223
- Serial 09030950
- Weight 13
- Working Working
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 21×20×19 in
- Shipping Type FedEx Ground
- Item Condition New other (see details)
Mettler Toledo Thornton Conductivity Sensors 58031223/413/235/014/002
**New Conductivity sensors in box. Unused and unsealed. Smarts and conductivity Sensors ready to be use. See photos for further details.
Includes:
(2) Mettler Toledo Thornton Conductivity Sensor: 243E223, model: 58031223
(2) Mettler Toledo Thornton Conductivity Sensor: UniCond, model: 58031413
(1) Mettler Toledo Thornton Conductivity Sensor: 58031235, model: 58031235
(1) Mettler Toledo Thornton Smart Conductivity Sensor: 58031014, model: 58031014
(1) Mettler Toledo Thornton Smart Conductivity Sensor: 580310002, model: 58031002
Thornton 243E223, Conductivity Sensor, 0.1 constant, 316LSS 1.5 inch Tri Clamp Fitting - 58031223 Cond Sensor 1.5Tri 0.1C SS
2-Electrode Analog Conductivity Sensor. This analog conductivity sensor is a 2-electrode sensor. Due to its highly polished 316L stainless steel electrodes, this sensor is suitable for hygienic applications such as pharmaceutical water.
Water Measurement in Multiple Industries
The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.
Traceable Calibration
Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.
Suitable for Hygienic Applications
The highly polished 316L stainless steel electrode and tri-clamp fitting make this conductivity sensor especially suitable for hygienic applications.
- Global Part #: 58 031 223
- US & Canada Part # 243E223
Operating Range (µS/cm) | 0.02 – 2,000 |
Temperature Sensor | PT 1000 |
Cell Constant | 0.1 cm-1 |
Connection | 1½ inch Tri-Clamp |
Cable | 1.5 ft (0.5 m) |
Connector | Standard |
Material certification | EN10204 3.1 & USP <88> Class VI |
Measurement Technology | Conductive |
Fitting material | 316L SS |
Insertion length | 86mm |
Model Family | Analog |
Hazardous Area Approvals | No |
Measured Pressure Resistance | 150 psig @ 311 °F and 450 psig @ 77 °F (10 bar @ 155 °C and 31 bar @ 25 °C) |
Electrode Material | SS 316L |
Primary Media/Application | Pharmaceutical Waters Pharmaceutical/Life Science Production |
Hygienic/Biocompatibility Approvals | Yes |
Process fitting | 1½" Tri-Clamp |
Cell Constant (accuracy) | ± 1% |
Electrode Configuration | 2-electrode |
Measurement Range | 0.02 - 2,000 µS/cm |
Sensor Material | 316L SS |
2-Electrode Conductivity Sensor.The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).
One Sensor for an Extensive Measurement Range
The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.
Superior Measurement Accuracy
The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.
High Accuracy in Pure Water
UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.
Operating Range (µS/cm) | 0.02 – 50,000 |
Temperature Sensor | PT 1000 |
Cell Constant | 0.1 cm-1 |
Connection | 1½ inch Tri-Clamp |
Cable | N/A |
Connector | n/a |
Material certification | EN10204 3.1 & USP <88> Class VI |
Measurement Technology | Conductive |
Fitting material | Titanium |
Insertion length | 86mm |
Model Family | UniCond |
Hazardous Area Approvals | No |
Measured Pressure Resistance | 203 psig @ 266 °F and 450 psi @ 77°F (14 bar @ 130 °C and 31 bar @ 25°C) |
Electrode Material | Titanium |
Primary Media/Application | Semiconductor Water |
Hygienic/Biocompatibility Approvals | Yes |
Sensor Material | Titanium |
Process fitting | 1½" Tri-Clamp |
Cell Constant (accuracy) | ± 1% for 0.02-5,000 µS/cm ± 3% for > 5,000 µS/cm |
Electrode Configuration | 2-electrode |
Measurement Range | 0.01 - 50,000 µS/cm |
Mettler Toledo Thornton Conductivity Sensor: 58031235, model: 58031235
Cond Sensor 2Tri 0.1C SS VP. 2-Electrode Analog Conductivity Sensor.This analog conductivity sensor is a 2-electrode sensor. Due to its highly polished 316L stainless steel electrodes, this sensor is suitable for hygienic applications such as pharmaceutical water.
Water Measurement in Multiple Industries
The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.
Traceable Calibration
Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.
Suitable for Hygienic Applications
The highly polished 316L stainless steel electrode and tri-clamp fitting make this conductivity sensor especially suitable for hygienic applications.
Operating Range (µS/cm) | 0.02 – 2,000 |
Temperature Sensor | PT 1000 |
Cell Constant | 0.1 cm-1 |
Connection | VP (IP 68) , 2 inch Tri-Clamp |
Connector | VarioPin |
Material certification | EN10204 3.1 & USP <88> Class VI |
Measurement Technology | Conductive |
Fitting material | 316L SS |
Insertion length | 104mm |
Model Family | Analog |
Hazardous Area Approvals | No |
Measured Pressure Resistance | 152 psig @ 311 °F and 450 psig @ 77 °F (12 bar @ 155 °C and 31 bar @ 25 °C) |
Electrode Material | SS 316L |
Primary Media/Application | Pharmaceutical Waters Pharmaceutical/Life Science Production |
Hygienic/Biocompatibility Approvals | Yes |
Process fitting | 2" Tri-Clamp |
Cell Constant (accuracy) | ± 1% |
Electrode Configuration | 2-electrode |
Measurement Range | 0.02 - 2,000 µS/cm |
Sensor Material | 316L SS |
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”