AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224
AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224

AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224

sku: 3375977
Out Of Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$600.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make N/A
  • Hertz 50Hz/60Hz
  • Model FE224
  • Serial FE224-0478
  • Weight 15
  • Voltage 120V
  • Working Working
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 17×17×13 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

AD Instruments Quad Bridge Amp Pressure, Force & Light Amplifiers FE224

**Unit is ready to be use and looks like anew. Everything in pictures are included. Buyer can expect same Item from pictures with 30-day warranty. See photos fr further details.

A four-channel, non-isolated bridge amplifier designed to allow a C Series Front End Inteface or traditional PowerLab to connect to most DC bridge transducers.  ADInstruments Bridge Amps are single-channel or multi-channel, non-isolated bridge amplifiers designed to allow a C Series Front End Interface or traditional PowerLab to connect to most DC bridge transducers, including commonly available force transducers, temperature probes, displacement transducers, pressure transducers, and similar devices. They are capable of supporting various powered transducers, and certain low impedance unpowered transducers. Various connectors & cables are available to interface a variety of transducers to a Bridge Amp, such as a Grass Adapter Cable for connecting to transducers with Grass connectors. The Bridge Amps are compatible with a range of ADInstruments and partnering products including:

  • Blood pressure transducer
    Used to measure arterial and venous blood pressure in animals. A BP (Blood Pressure) Amp is also available for invasive blood pressure measurements requiring full isolation.
  • Isotonic transducer
    Suitable for investigating isotonic contractions of isolated organs and tissue, and measuring small displacements in physiological preparations.
  • Pressure Catheter + Catheter interface cable
    Millar Mikro-Tip pressure catheters with pressure sensor(s) provides high-fidelity cardiovascular pressures (the heart and vascular system) at the source in small animals.
  • Physiological pressure transducer
    A highly accurate and robust piezo-resistive transducer.
  • Force transducers
    Ideal for isolated tissue studies with our range of tissue and organ baths
  • Low-drift instrumentation amplifier
  • Software-controlled zeroing
  •  Wide amplification range (±200 µV to ±5 V in 14 steps) for use with a wide range of transducers
  • A high impedance input (2 x 1 MΩ single-ended, 2 MΩ differential) ensures that the Bridge Amp will not load the transducer
  • Overload light to indicate whether the attached transducer is operating correctly or incorrectly

Specifications

  • Number of inputs: 1 (single), 4 (Quad) or 8 (Octal); 8-pin DIN
  • Input configuration: Differential
  • Amplification range: ±200 μV to ±5 V full scale in 14 steps (combined PowerLab and Bridge Amp)
    • ±5 V
    • ±2 V
    • ±1 V
    • ±500 mV
    • ±200 mV
    • ±100 mV
    • ±50 mV
    • ±20 mV
    • ±10 mV
    • ±5 mV
    • ±2 mV
    • ±1 mV
    • ±500 μV
    • ±200 μV
  • Amplification accuracy: ±0.5% (combined PowerLab & Bridge Amp)
  • Maximum input voltage: ±10 V
  • Input impedance: 2 x 1 MΩ (Single-ended); 2 MΩ (Differential)
  • Low-pass filtering: 1 Hz to 2 kHz in eight steps (software selectable)
  • Frequency response (-3 dB): 2 kHz maximum at all gains with the 2 kHz filter selected.
  • CMRR (differential): 100 dB at 50 Hz (typical).
  • Input noise: <1μVrms referred to input at highest gain

Excitation and Zeroing

  • Excitation voltage range: 0-20 volts DC (±10 V referred to ground), adjusted by external resistor
  • Transducer drive current: ±45 mA maximum
  • Zeroing circuitry: Software-controlled, either manual or automatic Internal offsetting range: ±10 V (1 V - 5 V range) ±1 V (100 mV - 500 mV range) ±100 mV (200 μV - 50mV)
  • Internal offset resolution: 16 bit (internal DAC) ± 32 000 steps about 0 V.
  • 1, 2, 5 V -310 μV/step
  • 100 mV, 200 mV, 500 mV - 31 μV/step
  • 200 μV to 50 mV - 3 μV/step

Control Port

  • I2C port: Power and control bus for front-end units.
  • Supports a number of front-ends dependent on the PowerLab.
  • Interface communications rate of ~50 Kbits/s.

Physical Configuration

  • Power requirements: 0.8 W (FE221); 2.5 W (FE224); 5.0 W (FE228) (without transducer attached)
  • Operating temperature range: 5 to 35 °C, 0 to 90% relative humidity (non-condensing)