Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)
Gilson UV/VIS 156 HPLC Detector (AS/IS)

Gilson UV/VIS 156 HPLC Detector (AS/IS)

sku: 3373727
1 In Stock
Condition : For parts or not working
Warranty : AS-IS
Region : US
$500.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Gilson
  • Hertz 50Hz/60Hz
  • Model UV/VIS 156
  • Serial 100L3H043
  • Weight 24
  • Voltage 120V/220V
  • Working Not Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 21×14×13 in
  • Shipping Type FedEx Ground
  • Item Condition For parts or not working

Gilson UV/VIS 156 HPLC Detector PARTS ONLY

***Unit is for sale AS/IS due to error upon startup, (front panel is loose, missing tabs & off the hinges). 

The 155 and 156 UV/VIS Detectors are intended to be used in a laboratory environment by trained technical personnel. The 155 and 156 UV/VIS Detectors are microprocessor-controlled absorbance detectors that provide dual wavelength detection. Both detector models are compatible components of a Gilson modular HPLC system. And, the 155 Detector with its front panel control is also compatible with other commercially available HPLC systems.


The 155 Detector can be controlled via its front panel or via TRILUTION® LC Software. The 156 Detector must be controlled via TRILUTION LC since it does not have an integral front panel display. 

The Gilson UV/VIS 156 detector is a component of a high-performance liquid chromatography (HPLC) system, specifically designed for detecting and quantifying compounds based on their absorption of ultraviolet (UV) and visible (VIS) light. HPLC is a powerful analytical technique used for separating, identifying, and quantifying chemical compounds in various samples.

 

Optics

  • Gilson’s optical design lets you monitor absorbance at any wavelength from 190 to 700 nm.
  • The detector has a sensitivity range of 0.001 to 2.0 AUFS (Absorbance Units, Full Scale).

 