Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W
Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W

Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W

sku: 3373705
1 In Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$9,500.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Rudolph Research Analytical
  • Hertz 50Hz/60Hz
  • Model A20766 APV/6W
  • Serial 80285
  • Weight 75
  • Voltage 120V/220V
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 22×39×18 in
  • Shipping Type Freight
  • Item Condition Pre-owned
  • Manufacturing Date 7/2006

Rudolph Research Analytical Automatic Polarimeter A20766 APV/6W

***Unit was tested as far as we could. Unit powers on without errors. All touchscreen & button functions normal. Buyer can expect the same item pictured with 30-day warranty. See photos for details.

Digital Polarimeter AUTOPOL® V, For Demanding Laboratories

The AUTOPOL® V Digital Polarimeter is designed for today’s FDA regulated analytical laboratories. Whether you are a Pharmaceutical, Nutraceutical or University Lab, the AUTOPOL® V has the standard measurement and compliance features you must have, including:

• TempTrol™ – Electronic cooling & heating from 15°-35°C

• Six Standard Wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm and 633nm

• 21CFR11 Compliance:  Electronic Signature and secure local electronic data storage

 

• Standard Accessories: TempTrol™ NIST Traceable Quartz Standard (single rotation), TempTrol™ 100mm Polarimeter Cell, TempTrol™ Temperature Validation Cell, Built-In Sample Measurement Probe.

The Autopol® IV and V Use Rudolph’s Exclusive TempTrol™ Electronic Temperature Control System

The USP <781> requires optical rotation measurements at 25°C ± .5°C (unless another temperature is specified). The European Pharmacopoeia requires optical rotation measurements made at 20° ± .5°C (unless another temperature is specified).

Whatever your temperature control needs are, the Autopol® IV and the Autopol® V Digital Polarimeter exclusive TempTrol™ System (Patent No. 6,717,665) makes your measurement in a few minutes without a waterbath or any type of water circulation.

The TempTrol™ System allows push-button temperature control of your 100mm cell, 200mm cell or Quartz Plate. Set the temperature, push “measure” and walk away. The Autopol® will heat or cool to a predefined temperature and then provide you with the result all in one easy step.

Patented TempTrol™ Technology Eliminates the Need for a Water Bath.

  • Temperature is selected via touch screen. Temperature selection of 20°C shown above.
  • Place the TempTrol™ cell in your TempTrol™ equipped Autopol® sample chamber to measure to within ±0.2°C of the USP, EP, JP or BP specified temperature (normally 20°C or 25°C ±0.5°C).

  • For improved temperature performance or when working with acids (HCl) use the measurement port in the body of the cell. This also allows the inlet and outlet ports to be capped to avoid evaporation, fumes and spillage.

  • Rudolph provides a temperature validation cell with every TempTrol™ system. The temperature validation cell along with an optional NIST traceable thermometer is designed to validate the temperature control performance of the digital polarimeter and cell to ±0.2°C.

 

The AUTOPOL® V Automatic Digital Polarimeter Offers Acid Resistance and Traceable Quartz Plates.

  • 6m HCl acid resistance: Silco Steel coating on the polarimeter chamber temperature transfer surface and a Hastelloy measurement cell with NIST certificate certifying optical path length.
  • To meet the FDA’s latest position on measurement bracketing, the Autopol® V Plus comes with a NIST traceable quartz plate with three rotations: +0.998° Arc, +10.998° Arc, -10.000° Arc. Each rotation has a NIST certificate.

 

Digital Polarimeter with Six Wavelengths and Only One Light Source

The AUTOPOL® V Automatic Digital Polarimeter comes standard with six wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm, 633nm. Wavelength selection is completely automatic and is accomplished by the push of a button. There are no lamps or filters to manually remove or insert.
The tungsten-halogen lamp employed in the AUTOPOL® V Polarimeter is a compact, reliable, low-cost, high intensity light source that allows any desired wavelength in the visible spectrum to be selected by means of a narrow band multilayer interference filter. The AUTOPOL® standard 10nm bandwidth is specified to permit high energy throughput and sensitivity for sample transmittances of only 0.01 % (O. D. = 4), while minimizing the effects of sample ORD and color.

 

Manufacturer's Specifications:

UTOPOL V SPECIFICATIONS
Measuring Mode Optical Rotation Specific Rotation Specific Rotation Plus Concentration User Defined Scale Sugar Degrees °Z(ISS)
Measuring Scale Degrees Arc, % Concentration
Measuring Range ± 89.99° Arc Optical Rotation
± 999.99°Arc Specific Rotation
0-99.9% Concentration
Resolution 0.001° Arc Optical Rotation 0.001% Concentration 0.001 Specific Rotation
Reproducibility 0.002° Arc
Standard Model Accuracy 0.002° up to 1°, 0.2% up to 5°, 0.01° above 5°
AP Model Specs Accuracy (546nm and 589nm): ±0.002° Arc over ±89.9° Arc Accuracy for other wavelengths is the same as the standard model Selectable Resolution 0.01°, 0.001°, 0.0001° Arc Optical Rotation
Prism Glan Thomson calcite quartz
Optical Wavelengths 365nm, 405nm, 436nm, 546nm, 589nm, 633nm (other wavelengths available)
Wavelength Selection Touchscreen Selectable: 6 standard
TempTrol™ Range Automatic Electronic Heating & Cooling 15°-35°C (Standard) ±0.2° C (Standard)
TempTrol™ Accuracy ±0.2°C
Temp. Probe Range 10°-100°C
Temp. Probe Accuracy ±0.1°C
Acid Resistance Hastelloy™ measurement cell and Silco Steel™ sample chamber (optional)
Measurement Time 4°/sec slewing rate & 5 sec nominal settling time
Light Source Tungsten-halogen 6V, 20W, avg. 2,000 hr life
Sample Chamber Accepts sample tubes up to 200mm
Data Storage 32 GB Non-removable Compact Flast
Communication Interface 3 - USB Ports 2 - RS232 Ports Ethernet Port for Network Connection
Calibration Automatic calibration by push-button
Operating System Windows® Embedded
Display 8 inch color LCD with LED backlight providing 800 x 600 resolution with 400 nits of luminance
User Interface Touchscreen
Automatic Sensitivity Control Measures samples with transmittance as low as 0.01 % (up to O.D. 4.0)
Input Power 100-240 VAC, 50/60 Hz
Operating Dimensions 30"W x 17"H x 10.5"D, 762mm W x 432mm H x 267mm D
Shipping Dimensions 30"W x 11.5"H x 17"D, 762mm W x 431.8mm H x 279.4mm D
Operating Weight 85 lbs (39 kg)
Shipping Weight 120 lbs. (54kg)