Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector
Thermo Scientific Accela PDA 80 Hz Detector

Thermo Scientific Accela PDA 80 Hz Detector

sku: 3370904
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$2,250.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Thermo Scientific
  • Hertz 50Hz/60Hz
  • Model Accela
  • Serial 930134
  • Weight 140
  • Voltage 120V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 25×19×38 in
  • Shipping Type Freight
  • Item Condition Pre-owned
  • Manufacturing Date 8-04-2010

Thermo Scientific Accela PDA 80 Hz Detector 60057-60140

***Unit was tested as far as we could. Detector will need new lamps. (Interior panel cover missing).  Unit has slight wear from normal use. Solvent rack included. See photos for details. 

 

Thermo Scientific Accela Systems provide a robust modular system with a large suite of integrated features to increase application flexibility and efficiency, permitting full customization for any laboratory. From routine industrial QA/QC to advanced drug discovery, from traditional HPLC to unsurpassed combined HPLC/UHPLC capabilities in one system, the Accela systems are designed for maximum performance, reliability and productivity.

The Thermo Scientific Accela High Speed PDA Detector uses Thermo Scientific LightPipe technology to ensure fast photo diode array detection with the highest sensitivity

• Proprietary LightPipe™ technology for highest sensitivity
• Specialized 1 cm path length, 2 µL LightPipe flowcell for U-HPLC separations
• 5 cm path length, 10 µL LightPipe flow cell provides the highest sensitivity available for HPLC applications
• Fiber-optic beam shaper provides maximum peak resolution
• Easy maintenance with integrated wavelength validation
• Reduced flow cell volume improves chromatographic efficiency

Manufacturer's Specifications:

Wavelength Range 190–800 nm at 1 nm increment
Wavelength Accuracy

 ±1 nm at 254 nm and 640 nm

Wavelength Calibration Using Holmium oxide solution
Wavelength Resolution 1.2 nm (512 pixel array)
Absorbance Non-Linearity < 5% at 2.0 AU at 257 nm
Absorbance Range -2.0 to +4.0 AU, 20-bit resolution
Drift < 1 mAU/hr after warm-up at 254 nm at a stable temperature (±1°C)
Light Source Pre-aligned Deuterium and Tungsten lamps
Rise Time User selectable: 0, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, or 10 sec
Scan Rate User selectable: 0.5, 1, 2, 4, 5, 10, 20, 40, or 80 Hz

 

Discrete Channels Three wavelength selectable channels
Short-Term Noise < 6 µAU/cm at 254 nm at 5 Hz
(20 Hz scan rate)
< 1.5 uAU/cm at 254 nm at 5 Hz
(40 Hz scan rate); typical
< 0.3 uAU/cm at 254 nm at 5 Hz
(80 Hz scan rate); typical
Warm-up Time 90 min required to meet noise and drift
specifications
Cell Dimensions 10 mm, 2 µL LightPipe flow cell
50 mm, 10 µL LightPipe flow cell
Cell Pressure Range 0–1000 psi
Analog Outputs 20-bit digital/analog conversion, unattenuated at 10 mV/AU, 100 mV/AU, or 1.0 V/AU
Diodes 512
Diode Spacing 1.2 nm

 

 

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”