Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is
Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is

Thermo Scientific Dionex ICS-Series VWD Variable W CLEARANCE! As-Is

sku: 3370822
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$1,249.00$2,500.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Thermo Scientific
  • Hertz 50Hz/60Hz
  • Model Dionex ICS-Series VWD
  • Serial 22040309
  • Weight 41
  • Voltage 120V/220V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 32×23×18 in
  • Shipping Type Freight
  • Item Condition Pre-owned

Thermo Scientific Dionex ICS-Series VWD Variable Wavelength Detector P/N 070220

 **This instrument was tested as far as we could. Unit is able to connect and communicate with software. Buyer can expect the same unit pictured and 30-day warranty. Does NOT include software. See photos for details. 

 

The Thermo Scientific Dionex™ ICS Series Variable Wavelength Detector (Dionex VWD) is a high-quality instrument designed for IC analysis applications requiring a UV-Vis detector and for LC analysis applications requiring an inert (PEEK™) flow path. The Dionex VWD can be used with the following Thermo Scientific Dionex systems: the ICS-5000 (analytical systems only), ICS-2100, ICS-1600, ICS-1100, and ICS-900 (as well as some legacy systems). The Dionex VWD can be used in numerous laboratory environments for routine analysis, as well as for sophisticated research tasks.

Two versions of the Dionex VWD are available: a single-channel version (P/N 070220) and a four-channel version (P/N 070221).

  • The detector is a dual-beam, variable-wavelength photometer with one measurement and one internal reference beam.
  • Two light sources, a deuterium lamp for ultraviolet detection and a tungsten lamp for visible and near-infrared wavelength detection, provide a wavelength detection range from 190 to 900 nm.
  • The four-channel detector measures at up to four wavelengths, by indexing between wavelengths several times per 
  • The wavelength accuracy can be verified via the built-in holmium oxide filter.
  • The detector is controlled with a PC (personal PC) 
  • Running Microsoft® Windows Vista® or Windows® XP and either the Thermo Scientific Dionex Chrome Leon® 7 Chromatography Data System or Chrome Leon® 6.8 Chromatography Data System. Chrome Leon 7 and Chrome Leon 6.8 also provide data acquisition and data processing functions.

NOTE Thermo Scientific Dionex Chrome Leon® Xpress software can provide real-time control and monitoring of the detector but does not include data management capabilities.

 

 Manufacturer's Specifications:

Optical System  Double-beam forward optics design (monochromator)
Dual-wavelength UV-VIS detector
Light Sources Deuterium lamp (for ultraviolet wavelength detection)
Tungsten lamp (for visible wavelength detection
Wavelength Range 190 to 900 nm
Wavelength
Accuracy
±1 nm (over detector lifetime)
Wavelength
Repeatability
±0.1 nm
Noise (single
wavelength)
<± 3.5 µAU (typical <± 2.5 µAU) under the following conditions:
Dry (dummy) flow cell, 254 nm, 1 second time constant,
deuterium lamp on only, 60 minutes or less of warm-up time
< 5.0 µAU (typical) under the following conditions:
Dry (dummy) flow cell, 520 nm, 1 second time constant, tungsten
lamp on only, 60 minutes or less of warm-up time
< 7.5 µAU (typical) under the following conditions:
Wet standard cell, 520 nm, flowing methanol at 1.0 mL/min,
1 second time constant, tungsten lamp on only, 60 minutes or less
of warm-up time
Noise (dual
wavelength

<± 25 µAU (typical <± 10 µAU) under the following conditions:
Dry (dummy) flow cell, 254 and 280 nm, 2 second times constant,
2 Hz data collection rate, deuterium lamp on only, 60 minutes or
less of warm-up time
< 30 µAU (typical <± 10 µAU) under the following conditions:
Dry (dummy) flow cell, 450 and 520 nm, 2 second times constant,
2 Hz data collection rate, tungsten lamp on only, 60 minutes or less
of warm-up time
< 50 µAU (typical <± 10 µAU) under the following conditions:
Wet standard flow cell, 450 and 520 nm, flowing methanol at
1.0 mL/min, 2 second time constant, 2 Hz data collection rate,
tungsten lamp on only, 60 minutes or less of warm-up time

 Drift  <1 x 10-4 AU/hour under the following conditions:
Dry (dummy) flow cell, 254 nm, deuterium lamp on only,
60 minutes or less of warm-up time, constant ambient conditions
(Temperature, humidity)
<1 x 10-4 AU/hour under the following conditions:
Dry (dummy) flow cell, 520 nm, tungsten lamp on only,
60 minutes or less of warm-up time, constant ambient conditions
(Temperature, humidity
Wavelength
Calibration
 Internal calibration with zero order and D-alpha line of the
deuterium lamp
 Wavelength
Verification
 Internal verification with holmium oxide filter
Data Collection
Rate (single
wavelength)
Adjustable, up to 10 Hz (single-channel Dionex VWD) or 100 Hz
(Four-channel Dionex VWD)
Data Collection
Rate (multiple
wavelength)
Adjustable, up to 5 Hz, depending on the number of wavelengths.
(2 to 4) and the distance between the wavelengths (in nm)
Optical Bandwidth 6 nm at 254 nm
Identification
System
Storage of identification and status information, including the
lamp type, serial number, number of lamps starts, lamp age, and
lamp intensity
Digital I/O  
Inputs Four digital inputs
Outputs Four digital outputs

 