Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is
Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is

Thermo Finnigan Surveyor PDA Detector CLEARANCE! As-Is

sku: 3370646
1 In Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$379.00$1,250.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Thermo
  • Hertz 50Hz/60Hz
  • Model Surveyor PDA Detector
  • Serial 701336
  • Weight 49
  • Voltage 120V/220V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 19×22×15 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned
  • Manufacturing Date 2004

Thermo Finnigan Surveyor PDA Detector

** Buyer can expect a working machine and 30-day warranty. Unit has slight wear from normal use. See photos for details.

The Surveyor PDA Detector is a full-featured, time-programmable, photodiode array detector. Detection can be carried out in the full ultraviolet-visible range from 190 to 800 nm. Data can be taken in this range at a rate of up to 20 Hz with 20-bit digital conversion. The Surveyor PDA Detector is a bench-top unit for inclusion in the
Surveyor liquid chromatography system. It is controlled remotely over an
Ethernet communication link from a PC using Chrom Quest or Xcalibur
software. The detector consists of a dual-light source, an optical bench, a
photodiode array, a low voltage power supply, several printed circuit boards
(PCBs), and four status LEDs.

Manufacturer's Specifications:

  • Wavelength Range: 190 nm to 800 nm continuous
  • Wavelength Accuracy: ±1 nm at 254 nm and 656 nm
  • Digital Wavelength Resolution: 1.2 nm
  • Absorbance Range: í2.0 AU to +4.0 AU, 20-bit resolution
  • Drift: ≤ 1 MAU/h after warming up at 254 nm at a stable temperature (±1 ºC)
  • Warm-up: 90 min to meet noise and drift specifications
  • Linearity: deviation ≤ 5% up to 2.0 AU at 256 nm
  • Scan Rate: 0.5, 1, 2, 4, 5, 10, or 20 Hz (user selectable)
  • Rise Time: 0.0, 0.1, 0.2,0.5, 1, 2, 5, or 10 s (user selectable)
  • Cell Dimensions: ___PP_____ /_/LJKW3LSH
  • Cell Pressure Rating: 1000 psi
  • Diodes: 512
  • Diode Spacing: 1.2 nm.
  • Light Source: Deuterium and tungsten-halogen lamps, pre-aligned
  • Filter Wheels: Standard Filter Wheel: 2 position wheel, 1 open position and 1 Holmium oxide/perchloric acid filled cuvette, NIST traceable.
    Optional Linearity Calibration Wheel: 5 position wheels, 1 with perchloric
    acid blank and 4 cuvettes with different concentrations of potassium
    dichromate in perchloric acid, NIST traceable
  • Analog Outputs (2): 20-bit digital / analog conversion, unattenuated at 10 mV/AU, 100 mV/AU, or 1.0 V/AU
  • Remote Controls: Start, Zero, RJ45 Ethernet interface for Chrom Quest
  • Operating Temperature: +10 to +30 ºC
  • Operating Humidity: 5% to 95% non-condensing relative humidity