NuAire NU-5720 Direct Heat CO2 Incubator Dual Chamber Double Stack
- Make NuAire
- Hertz 50Hz/60Hz
- Model NU-5720
- Serial 183766010518 & 183821010518
- Weight 540
- Voltage 120V
- Working Working
- Includes Power Cord
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 33×31×83 in
- Shipping Type Freight
- Item Condition Pre-owned
- Manufacturing Date 2018
NuAire NU-5720 Direct Heat CO2 Incubator Dual Chamber Double Stack
**This double stack incubator has been tested for basic functionality. Unit has slight scratch on right side. See photos for further details.
In-VitroCell model NU-5720 is a CO2 Incubator designed to control relative humidity (RH) levels in the growth chamber better through a sensor and reservoir in place of a water pan. The RH control method allows for greater accuracy to maintain a stable RH percentage by injecting water vapor into the growth chamber to meet the setpoint. RH control is perfect for research samples prone to desiccation or dryer environments.
Features:
- NuTouch Electronic Control System
- Dual Decontamination Cycles
- Coved Interior Corners
- Closed Loop HEPA Filtration
- Dual Wave IR (Infrared) Sensor
- RH Sensor and Evaporator Tank
- Direct Heating Elements
- Perimeter Door Heating Element
- Air Pump External to Chamber
- HEPA Filter External to Chamber
- Inner Door with Cam Action Door Handle
- Water Pan for Calibrations Only
- Dual Temperature Sensor Probes
- Inner Door Gasket
- Four (4) Shelves
- Eight (8) Shelf Guides
- Four (4) Wall Brackets
- Remote Alarm Output Contacts
- 4 to 20 mA Analog Output
- RS-485 Communication
- USB Port for Data Download
- CO2 Sample Port
- Adjustable Leg Levelers
- Access Port and Plug with Breathing Hole(s)
PRECISE HUMIDITY CONTROL
Relative humidity levels up to 90% are achieved in the growth chamber through the use of a 3-liter reservoir external to the chamber. The chamber air is routed through the water vapor saturated the air in an evaporate box to add humidity when the RH sensor indicates more humidity is needed to meet set point.
DUAL DECONTAMINATION CYCLES
The direct heat technology enables the use of a 145°C dry and 95°C humidified decontamination cycle that can be conveniently run overnight in just 8 hours without removing the CO2 or temperature sensors. The NuTouch control system steps the user through the process with on screen instructions and displays progress throughout each phase of the complete cycle.
Constant Contamination Control
Advanced features mitigate risks due to contamination. Using a slight positive pressure within the chamber eliminates contaminated laboratory air entering the growth chamber. Air and gas pass through 99.99% @ 0.3 micron efficient HEPA filters before entering the chamber resulting in conditions similar to an ISO Class 5 cleanroom. Smooth rounded corners eliminate potential hiding places for contaminates. An overnight procedure running a decontamination cycle at 145° Celsius dry or 95° Celsius humidified is the perfect solution for the fight against contamination. Contamination control is just one more reason NuAire is the safer choice for your laboratory.
Infrared (IR) Sensor
A single source dual wave infrared (IR) sensor controls CO2 levels within the growth chamber to maintain an optimal PH. The wavelengths used are absorbed only by CO2, making the measurements insensitive to other components such as water vapor. Advanced design provides a stable output minimizing drift, and requires less frequent calibrations.
Uniform Temperature
The Direct heating elements or the water jacket are wrapped in high density insulation which surrounds the growth chamber. Dual temperature sensor probes relay information back to the NuTouch Electronic Control System and make adjustments as needed.
Manufacturers Specifications:
Access Port Location | Right Side |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Chamber Air Circulation Method | Air Pump |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Chamber Heater(s) Location | Sides, Bottom, Top and Back of Chamber |
Chamber Jacket Technology | Air Jacket via Two Axial Fans Drawing Air into Shell |
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Control System | NuTouch |
Data Output Features | RS-485, USB, 4-20mA |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Height Inches (mm) | 36.188 (894) |
Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Segmented Doors | Optional Set of 4 Inner Doors |
Inner Doors | One, Sectioned Optional |
Insulation | High Density Insulation with High "R" Rating |
Interior Depth Inches (mm) | 20.678 (525) |
Interior Door Seal | Silicone Rubber Gasket |
Interior Height Inches (mm) | 24.000 (610) |
Interior Material | Highly Polished Type 304L 16 Gauge Stainless Steel |
Interior Volume Cubic Feet (Liters) | 5.65 (160) |
Interior Width Inches (mm) | 20.250 (514) |
Power Cord Length Foot (Meter) | 8 (2.5) |
Remote Alarm Terminals | Standard |
RH Accuracy | 95% +5% / -3% |
RH Control Method | Evaporator Box |
RH Control Logic | Fixed algorithm/manual environmental adaptable |
RH Control Range | Ambient dependent to 95% |
RH Display Resolution | 0.1% |
RH Evaporator Box Capacity | 3L |
RH Recovery | 90% +5% / -3% within 25 minutes on average |
RH Sensor Type | Precision capacitance bulk-polymer |
RH Water Pan Capacity | 2L (Recommended Fill 1.5L) (For Calibration Only) |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Material | Stainless Steel |
Shelf Width Inches (mm) | 18 (457) |
Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Direct Heat |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.35°C @ 37°C |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |