Omega OM-USB-TC 8 Channel Thermocouple Input USB Data Acquisition Module
- Make Omega
- Model OM-USB-TC
- Serial 2109C48
- Weight 7
- Working Working
- Includes User Manuals
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 19×16×10 in
- Shipping Type FedEx Ground
- Item Condition New
Omega OM-USB-TC 8 Channel Thermocouple Input USB Data Acquisition Module
**USB Data Module new in seal package in Box with cable. Buyer can expect a working item. See photos for further details.
The OM-USB-TC is a USB 2.0 full-speed, thermocouple input module that is supported under popular Microsoft Windows operating systems e OMB-DAQ-2416 Series and OM-USB. Series Software User’s Guide. The OM-USB-TC is fully compatible with both USB 1.1 and USB 2.0 ports. The OM-USB-TC provides eight differential thermocouple input channels. Eight independent, TTL-compatible digital I/O channels are provided to monitor TTL-level inputs, communicate with external devices, and to generate alarms. The digital I/O channels are software programmable for input or output. With the OM-USB-TC, you can take measurements from type J, K, R, S, T, N, E, and B thermocouples. The OM-USB-TC provides two integrated cold junction compensation (CJC) sensors for thermocouple measurements. An open thermocouple detection feature lets you detect a broken thermocouple. An on-board microprocessor
automatically linearizes the measurement data. The OM-USB-TC is a standalone plug-and-play module which draws power from the USB cable. No external power supply is required. All configurable options are software programmable.
Specifications
Parameter | Four dual 24-bit, Sigma-Delta type |
Number of channels | 8 differential |
Input isolation | 500 VDC minimum between field wiring and USB interface |
Channel configuration Differential input voltage range |
Thermocouple sensor type: ±0.080 V |
Absolute maximum input voltage |
±25 V power on, ±40 V power off |
Input impedance | 5 Gigohm, min. |
Input leakage current | Open thermocouple detect enabled: 105 nA max. |
Normal mode rejection ratio | fIN = 60 Hz / 90 dB min |
Common mode rejection ratio | fIN = 50 Hz/60 Hz / 100 dB min. |
Resolution | 24 bits |
Input coupling | DC |
Warm-up time | 30 minutes min |
Open thermocouple detect | Automatically enabled when the channel pair is configured for thermocouple sensors. The maximum open detection time is 3 seconds |
CJC sensor accuracy | 15 °C to 35 °C / ±0.25 °C typ / ±0.5 °C max. |
CJC sensor accuracy | 0 °C to 70 °C / -1.0 to +0.5 °C max |
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”