  • Make Powervar
  • Hertz 50Hz/60Hz
  • Model GPI2000
  • Serial 7401554R1030020
  • Weight 600
  • Voltage 240V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 40×23×31 in
  • Shipping Type Freight
  • Item Condition Pre-owned

POWERVAR Global Power Interface 2000 Power Supply

incorporate a low impedance isolation transformer, as well as a surge diverter and power line filter to eliminate noise, spikes, and transients before they have a chance to wreak havoc on your equipment. Voltage distribution and conditioning all in one solution

Standard equipment includes safety interlocks, emergency machine off (EMO), casters, and lockout/tagout breaker. 

EMO, safety interlocks, lockout/tagout breaker, and casters are standard on all models

** Unit has been tested for basic functionality and has slight cosmetic blemishes from normal use. One of the wheels does not maneuver smoothly but does not interfere with functionality of the unit. 

 

Manufacturer Specifications:

Model ABC15.0-XXD20Y
Input Voltage 208/240/480/600 delta connection (4 wire)
Ouput Voltage 208/120 wye (5 wire)
Frequency 60 Hz. only
Continuous Capacity 15 kVA
BTU/Hr. Output 1536
Efficiency > 97% (at full load, unity power factor)
Step Load Change + 0.8% (at unity power factor)
Noise Rejection With unit under power and the isolation transformer configured for a transformation
ratio of 1:1 and with an ANSI/IEEE C62.41, Category A pulse applied either normal mode
or common mode at the input, the noise output voltage will be less than 10 volts normal
mode and less than .5 volts (½ of one volt) common mode in all four quadrants
(CM-NM, NM-NM, CM-CM, NM-CM).
Surge Voltage Withstand Tested under power to ANSI/IEEE C62.41, Category A & B (formerly IEEE587-1980).
Power conditioner tested to withstand up to 6000 volts @ 3000 amp ringwave and unipo
lar impulse.
Construction Materials Transformer wires are copper and insulated with Class H materials. Windings are insu
lated with Nomex paper insulation before vacuum varnishing. Internal wiring is a mini
mum of 200 degree C rated and sleeved with Class H materials. Grain oriented
silicon iron cores are constructed using 14 mil. laminations interleaved one to one. Eddy
currents are minimized and external magnetic fields are below 0.1 oersted (at 12 inches
distance in any direction). Unit is RoHS compliant.