Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is
Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is

Agilent G1888A Network Headspace Sampler CLEARANCE! As-Is

sku: 3370388
Out Of Stock
Condition : Pre-owned
Warranty : AS-IS
Region : US
$3,499.00$7,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Agilent
  • Hertz 50Hz/60Hz
  • Model G1888A
  • Serial IT00639027
  • Weight 142
  • Voltage 120V/220V
  • Working Working
  • Includes Power Cord
  • Warranty AS-IS
  • Dimensions 29×23×30 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

Agilent G1888A Network Headspace Sampler

**This instrument has been tested for basic function. Sampler initializes upon startup and passed self check. This unit has some scratches on side panel chipped paint on front. See photos for details. 

The Agilent G1888 Headspace Sampler lets you automatically introduce volatile compounds from virtually any sample matrix directly into a GC or GC/MSD system. It features an inert sample pathway for superior chemical performance without analyte
degradation or loss. And its high sample capacity and increased sensitivity ensure excellent performance for a wide range of analysis.

Built-in performance and reliability

From sampling… to detection… to data analysis and reporting… Whether your application is pharmaceutical, food safety, environmental, or forensic… The G1888 is a fully integrated system that gives you unsurpassed confidence in your results.

 Features:

  • 70-sample tray and 12 positions in the heating oven allow unattended overnight operation for many applications
  • Automated constant heating time is employed with optimized sample overlapping for maximum sample throughput in the minimum amount of time
  • Deactivated sampling path, from sampling needle to transfer line, is standard so coupling with an inert 7890A or 6890N Volatiles Interface achieves complete chromatographic system inertness
  • Controlled temperature range from 40 degrees C to 230 degrees C makes it possible to analyze semi-volatiles at temperatures over 200 degrees C, as well as traditional applications for low boiling point analytes
  • Heated zones can be turned off, which allows analyses at ambient conditions for biological or extremely thermally sensitive analytes
  • Incorporates two modes of multiple headspace extraction (MHE) in addition to routine single extraction (one sampling per vial)
  • Multi-puncture extraction with up to 100 extractions per vial is possible for the analysis of samples in unusual matrices
  • A 'concentration mode' of MHE allows multiple extractions from a vial to be made, followed by the start of the GC run after the last extraction
  • Includes several convenient testing and troubleshooting features, including a set of four pre-stored chemical test methods, a semi-automated leak test, and a detailed power-on self-test
  • Instrument control can be achieved using the GC ChemStation, MSD Productivity ChemStation and MSD Security ChemStation, or Cerity NDS for Pharmaceutical QA/QC
  • Instrument control is integrated with drop-down menus for ease of method setup. The existing sequence table is used to set up analyses, maintaining optimized sample overlap and constant heating time.
  • An event log function tracks every headspace sampler operation and reports any temperature and pressure deviation compared to the set point in compliance with 21 CFR Part 11
  • Built-in keypad control enables compatibility with all GCs

 

Manufacturers Specifications:

Sample Capacity

  • Holds 70 vials in tray. Twelve position oven for optimized sample overlapping constant time heating.

Sample Vials

  • Standard crimp top or screw cap vials, 20 mL, 10 ML. No adaptor required for 10-mL sample vials.

Mode of Operation

  • Shaking with choice of off, low, or high.
  • Constant heating time (CHT) mode for each sample. Overlapping up to 12 vials for maximized sample throughput
  • Multiple headspace extraction (MHE) mode with up to 100 extractions per vial for method development and validation or for analysis of sample in unusual matrices
  • Multiple headspace extraction concentration (MHC) mode, with up to 10 extractions from 1 vial made followed by one GC start after the last extraction to increase sensitivity

Zone Temperature

  • All temperature zones can be set off
    Oven heating: 40 °C to 230 °C in 1 °C increments; 0.5–999 min in 0.1 min increments
  • Loop/Valve: 45 °C to 250 °C
  • Transfer line: 50 °C to 250 °C

Sample Pathway

Inert deactivated path from sample needle to transfer line. Transfer line length: 85 cm. Sample loop: 1 mL (standard), 3 mL (option)

Pneumatic Control

  • In-unit switch connection between: Built-in manual pneumatics (pressure regulator and flow controller) and GC built-in electronic pneumatic control (EPC)

  • Interfacing with GC
    Volatile inlet (VI) or other standard GC inlet

Communication

  • LAN; RS-232; Remote start/stop

System Control

  • Control and monitoring by full function control keypad and built-in multiline display. Features:
    • Parameter set up
    • Store up to four user defined headspace methods (there are also five preset methods)
    • Detailed power-on self test
    • Built-in leak test routine
    • Update firmware via LAN or RS-232
    • Monitor set and actual values, as well as, operation status

Environmental Conditions

  • Operation: 10 °C to 35 °C
  • Storage: –40 °C to 70 °C
  • Humidity: 5% to 95%
  • Line voltage: 100–240 V ±10%
  • Power required: 750 VA maximum