Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813
Waters Synapt G2 Mass Spectrometer 186004813

Waters Synapt G2 Mass Spectrometer 186004813

sku: 3370019
Out Of Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$10,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Waters
  • Hertz 50Hz/60Hz
  • Model Synapt G2
  • Serial UCA186
  • Weight 671
  • Voltage 220V
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 70×39×69 in
  • Shipping Type Freight
  • Item Condition Pre-owned
  • Manufacturing Date 09/2010

Waters Synapt G2 Mass Spectrometer 186006532

**This Waters Synapt G2 Mass Spectrometer has been tested for basic functionality and is deemed to be in working condition. System will need to be validated/calibrated to ensure accurate results. Inquire if validation/calibration is available from seller for an additional cost. Unit has slight cosmetic defect on side of ion source and small crack on back panel. See photos for further details. Buyer will receive a 30 day warranty.

The Synapt G2 platform from Waters provides a new dimension of performance to drive your scientific discovery like never before. We’ve combined QuanTof – breakthrough quantitative Tof technology – and enhanced High Definition MS technologies to provide you with intuitive operation, application flexibility, and a totally new level of performance for all your applications. Synapt G2 MS is a high resolution exact mass MS/MS platform designed to get you to the right result, faster – no matter how challenging your application is – whether you specialize in metabolite profiling, proteomics, biomarker discovery, biopharmaceuticals, or screening applications.

 The Waters Synapt G2 Mass Spec is fitted with LockSpray Exact Mass Ionization Source

The LockSpray dual electrospray ion source optimizes the co-introduction of analyte and lock mass compound directly into the ion source, providing authenticated exact mass measurement in MS and MS/MS modes to within 5 ppm RMS mass accuracy (3 ppm for Xevo QTof MS and 1 ppm for Xevo G2 Tof series, Xevo G2 QTof series and SYNAPT G2 series).

The increased specificity associated with exact mass measurement provides you with improved efficacy in compound or fragment identification in metabolite profiling and proteomics applications.

Traditionally, to obtain valid exact mass measurement, an internal reference or “lock mass” was used to correct for changes in environment or experimental conditions over the course of the analysis. This was achieved by “teeing in” a suitable reference compound to the main analyte flow. However, this approach often suffered from ionization suppression, potential mass interferences and solvent gradient effects.

The LockSpray source design overcomes these limitations.

 

Manufacturers Specifications: 

TOF Mass Resolution in Positive Ion

  • Sensitivity Mode-10,000 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956)
  • Resolution Mode- 20,000 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956)
  • High Resolution Mode   40,000 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956)

TOF Mass Resolution in Negative Ion

  • Sensitivity Mode-10,000 FWHM measured on the (M - 4H)4- isotope cluster from bovine insulin (m/z 1431)     
  • Resolution Mode-20,000 FWHM measured on the (M - 4H)4- isotope cluster from bovine insulin (m/z 1431)     
  • High Resolution Mode- 40,000 FWHM measured on the (M - 4H)4- isotope cluster from bovine insulin (m/z 1431)

Positive Ion MS Sensitivity

  • Sensitivity Mode-The peak at m/z 556 from a solution of 50 pg/μL leucine enkephalin in 50/50 acetonitrile/water    + 0.1% formic acid, infused at a flow rate of 5 μL/min, will have an intensity of greater than    1700 ions per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin) and the mass range will be set to a maximum of 1200 m/z.
  • Resolution Mode- The peak at m/z 556 from a solution of 50 pg/μL leucine enkephalin in 50/50 acetonitrile/water    + 0.1% formic acid, infused at a flow rate of 5 μL/min, will have an intensity of greater than    850 ions per second. The instrument will be tuned to 20,000 resolution (as demonstrated on     bovine insulin) and the mass range will be set to a maximum of 1200 m/z.     
  • EDC-The peak at m/z 556 from a solution of 10 pg/μL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, infused at a flow rate of 5 μL/min, will have an intensity of greater than    1000 ions per second. The instrument will be tuned to 20,000 resolution (as demonstrated on bovine insulin), with sensitivity set to a maximum at 556 m/z.
     

Negative Ion MS Sensitivity

  • Sensitivity Mode - The peak at m/z 503 from a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water (no    additives), infused at a flow rate of 5 μL/min, will have an intensity of greater than 1800 ions per    second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin),    and the mass range will be set to a maximum of 1200 m/z. 
  • Resolution Mode-The peak at m/z 503 from a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water (no    additives), infused at a flow rate of 5 μL/min, will have an intensity of greater than 900 ions per    second. The instrument will be tuned to 20,000 resolution (as demonstrated on bovine insulin),    and the mass range will be set to a maximum of 1200 m/z.

Positive Ion MS/MS Sensitivity

  • Sensitivity Mode-Using a [Glu1] -Fibrinopeptide B solution of 100 fmol/μL, at a flow rate of 5 μL/min and with the    instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the    most intense y” sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 m/z) will be greater than 130 ions per second. The instrument mass range will be set    to a maximum of 2000 m/z.
  • Resolution Mode-Using a [Glu1] -Fibrinopeptide B solution of 100 fmol/μL, at a flow rate of 5μL/min and with the    instrument tuned for 20,000 resolution (as demonstrated on bovine insulin), the intensity of the most intense y” sequence ion from the MS/MS spectrum of the doubly charged precursor ion    (785.8 m/z) will be greater than 65 ions per second. The instrument mass range will be set to a maximum of 2000 m/z.

Negative Ion MS/MS Sensitivity

  • Sensitivity Mode-  Using a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water, at a flow rate of 5 μL/min    and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the fragment ion at 179.1 m/z in the MS/MS spectrum of the precursor ion at 503.2 m/z    will be greater than 130 ions per second. The instrument mass range will be set to a maximum of 1200 m/z.
  • Resolution Mode- Using a solution of 500 pg/μL raffinose in 70/30 acetonitrile/water, at a flow rate of 5 μL/min and    with the instrument tuned for 20,000 resolution (as demonstrated on bovine insulin), the intensity   of the fragment ion at 179.1 m/z in the MS/MS spectrum of the precursor ion at 503.2 m/z will be greater than 65 ions per second. The instrument mass range will be set to a maximum of 1200 m/z.

Mass Scale Calibration Accuracy

  • The mass measurement accuracy of the instrument in High Resolution mode, using internal lock   masses, is such that the RMS error between the measured and the accepted masses of peaks which    have sufficient intensity, and are free from interference from other masses, will be less than 1 ppm over the range 150 to 800 m/z.

Mass Measurement Accuracy

  • The mass measurement accuracy of the instrument, in High Resolution mode, will be better than 1 ppm RMS, based on 10 consecutive repeat measurements of the [M + Na]+ ion of raffinose  (m/z 527.1588), using the [M + H]+ ions of leucine enkephalin (m/z 556.2771) and    4-acetamidophenol (m/z 152.0712) as the LockSpray lockmasses. Analyte and lockmass peaks must have sufficient intensity and be free of interference from other masses.

Mass Range

  • The TOF mass range is 20 to 100,000 m/z in Resolution mode, and 20 to 32,000 m/z in High Resolution mode. The m/z transmission range for a quadrupole in non-resolving mode is 20 to    16,000 m/z for a 4000 m/z quadrupole, 20 to 32,000 m/z for an 8000 m/z quadrupole, and 90 to 100,000 for a 32,000 m/z quadrupole.

Acquisition Rate

  • Spectra can be acquired at a rate of 20 scans per second, except in pDRE mode, when the maximum rate is 10 scans per second.

Dynamic Range

  • The dynamic range in High Resolution mode, defined as the range of peak intensities that will give better than 3 ppm accurate mass RMS for 10 sec of data without pDRE (programmable Dynamic Range Enhancement), is at least 4 orders of magnitude, when measured on the m/z 556.2771    peak from leucine enkephalin

High Mass Precursor Selection

  • Applicable to instruments with 8000 m/z and 32,000 m/z quadrupoles only. The low energy MS/MS spectrum of m/z 5569.1 from a solution of 2 μg/μL sodium iodide in 50/50 isopropanol/water will contain only m/z 5569.1 and its fragments. The intensity of the largest fragment ion will be less than 5% of the intensity of the precursor ion. MS/MS data will  be acquired over the mass range 100–8000 m/z, with collision energy of 10 eV.

 