Waters HPLC 1525 Binary Pump System with 2487 Dual Absorbance Detector
- Make Waters
- Hertz 50Hz/60Hz
- Model Waters 2487 Detector & 1525 Binary HPLC Pump
- Serial L06487
- Weight 167
- Voltage 120V/220V
- Working Working
- Includes ALL cables (power and data)|Computer with Software
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 34×48×35 in
- Shipping Type Freight
- Item Condition Pre-owned
Waters 1525 Binary HPLC Pump is integrated, high-pressure, binary HPLC pump that feature on-board pulse dampening and efficient mixing. Their pulse-free solvent flow, from analytical to semi-preparative flow rates, makes them ideal for use with highly sensitive detectors.
The Waters 1525 Binary HPLC Pump is designed for use with 2 to 4.6 mm I.D. columns in routine LC and LC/MS applications. They have a programmable flow-rate range of 0.00 to 10.00 mL/min in 0.01 mL increments.
Waters 2487 (DAD) is the most sensitive and versatile absorbance detector for HPLC. Designed to provide the highest performance in UV/Vis detection, the 2487 detector offers the superior sensitivity required for detection of minor impurities, with the linear dynamic range to simultaneously quantitate major and minor components for both routine and complex applications.
**Includes Computer with Breeze 3.30 Software
Manufacture Specification
Waters 1525
Control |
MassLynx 4.0(SP1) and Breeze 3.3 software |
Programmable flow rate |
0.00 to 5.00 mL/min, in 0.01-mL/min increments |
Flow precision |
2 secs, SD, replicates based on retention time or volumetric measure at 0.2 mL/min 1000-2000 psi backpressure, PQ test (each pump individually)1 |
Flow accuracy |
2% of setting at 0.1mL/min using degassed methanol at 1000-2000 psi backpressure (each pump individually) |
Maximum operating pressure |
6000 psi (41,370 kPa, 400 bars) |
Operating pressure limits |
Software programmable high and low pressure limits; user selectable in psi, kPa,bar |
Delay volume |
<30 µL (without mixer) , 100 (with one 50 µL mixer) |
Gradient accuracy |
<1% of setting (typical) between 10 to 90%, and 1000 psi backpressure (methanol: methanol with propylparaben and one 50 µL mixer) |
Gradient Precision |
<0.5% RSD (typical) between 10 to 90%, 0.1 mL/min, and 1000 psi backpressure (methanol: water with octanophenone and one 50 µL mixer) |
Pressure Ripple (one pump) |
<2.0% at 0.5 mL/min, degassed methanol, at 1000 to 2000 psi backpressure |
Gradient Ripple |
<1.5% normalized to full scale between 10 to 90%, 0.1 mL/min, and 1000 psi backpressure (methanol: methanol with propylparaben and one 50 µL mixer) |
Waters 2487
Wavelength Range |
190 to 700 nm |
Bandwidth |
5 nm |
Wavelength Accuracy |
± 1 nm |
Wavelength Repeatability |
± .10 nm |
Noise, single wavelength |
< ± 0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant (TC) |
Noise, dual wavelength |
< ± 2.5 x 10-5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant (TC) |
Linearity |
5% at 2.5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant (TC) |
Drift |
1.0 x 10^4 AU/Hour/degrees Celcius at 254 nm (after 1 hour warmup) |
Sensitivity setting range |
0.0001 to 4.0000 AUFS |