Beckman Gold HPLC System
- Make Beckman
- Hertz 50Hz/60Hz
- Model System Gold
- Serial 482-1115
- Weight 187
- Voltage 120V/220V
- Working Working
- Includes Power Cord
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 30×51×30 in
- Shipping Type Freight
- Item Condition Pre-owned
The System Gold HPLC manufactured by Beckman, which is designed to be particularly useful in life sciences laboratories, consists of several instrument modules that are used in various combinations, consumables, accessories and software tailored to specific applications, such as drug metabolism assays.
Includes:
- Beckman System Gold 125 Solvent Module
- Beckman System Gold 507 Autosampler
- Beckman System Gold 168 Diode Array Detector
Manufacture Specification
Beckman System Gold 125 Solvent Module
- Flow range: 0.01 – 10.0 ml/mi for each pumping mechanism
- 0.1 mL increments; max flow rate 10mL/min
- Preparativ; 0.03 to 30.0 mL/min with optional preparative liquid head for each pumping mechanism. Max iscoratic flow rate 30 mL/min
- Reproducibility: +/- 1% or 0.003 mL/min. whichever is greater
- Composition range: 0-100% in 0.01 increments
- Operating pressure: 0-6000 p.s.i.
- Operating temp: 4 – 40 degrees C
- Maximum solvent temp: 75C
- Piston displacement: 90ul prepartive 243uL
- Program functions: flow gradient curve composition external contacts audible alarm
- High Pressure Limit: Selectable 20-6500 psi
- Low Pressure Limit: Selectable 0-6490 psi
Beckman System Gold 507 Autosampler
Sample Vial Size: 12 X 32mm | |
Needle Wash Volume: | 30-999 microliters |
Injection Size | |
Filler-Loop: | 10-199 microliters |
Partial-Loop: | <50% Loop Volume |
Sample Conservation Mode: | <40% Loop Volume |
Digital Dispenser | |
Loop Fill Rate: | 1 microliter/second |
Typical Carryover | |
30-microliter Flush: | <0.2% |
50-microliter Flush: | <0.1% |
Sample Requirements | |
Full Loop: | 1.5 X Loop Volume + Flush Volume |
Partial-Loop: | Inject Volume + Flush Volume |
Sample Conservation Mode: | Inject Volume + 2-microliters (with micro vial) |
Beckman System Gold 168 Diode Array Detector
- Wavelength range: 190 to 600 nm
- Diodes: Single array, 512 diodes, 1 nm per diode
- Bandwidth: Adjustable 4 to 410 nm
- Scan speed: Adjustable 0.5 to 16 Hz
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”