Description
The ARCHITECT ci4100 combines ARCHITECT c4000 and ARCHITECT i1000SR instruments − offering lower volume laboratories the enhanced efficiency and productivity employed by larger volume laboratories.
The ARCHITECT ci4100 offers a maximum throughput of up to 900 tests per hour, including 800 clinical chemistry and 100 immunoassay tests. Featuring a load-up capacity of 180 samples with 35 priority positions, the ARCHITECT ci4100 has up to 115 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
**Unit is missing track for robotic arm. Carousel does not rotate when button is pressed but lid opens when button is pressed. Computer needs work and software. See attached pictures for more information.
Specifications
Methods | c4000: Photometric, Potentiometric, Turbidimetric; i1000SR: CHEMIFLEX |
Maximum Throughput | Up to 900 tests/hour |
Sample Types |
c4000: Serum, Plasma, Whole Blood, Urine, CSF; i1000SR: Serum, Plasma, Whole Blood, Urine |
Sample Tubes | Height: 72–102 mm Diameter: 9.6–16.1 mm |
Sample Cup | Yes (50 µL dead volume) |
Sample Capacity | 180 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | c4000: 1.5–35 µL Average: 6 µL; i1000SR: 10–150 µL Average: 62 µL |
Automatic Dilution | Yes |
Sample Probe Carryover | ≤0.1 parts per million |
Reagent Capacity | Up to 115 refrigerated positions plus patented ISE (Na+, K+, and Cl-) |
Reagent Type | c4000: >95% liquid ready-to-use; i1000SR: >100% liquid ready-to-use |
Reagent Onboard Stability | c4000: 5–65 days Average: 40 days; i1000SR: 14-30 days |
Calibration Frequency | c4000: 1–60 days Average: 25 days; i1000SR: Calibrate with new lot number, if controls are out of range or if specified otherwise within the package insert |
Sample, Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | Yes |
Sample Interference Measurement | Yes, hemolysis, icterus, and lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard, and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Electrical Requirements | c4000: AC 180-264V, 47-63 Hz, 20 amp; i1000SR: AC 110-120V or 200-240V, ±10%, 50 or 60 Hz self-adjusting |
Water Requirements | c4000: Deionized water 15 liters/hour during normal operation, 25 liters/hour maximum; i1000SR: Purified water to dilute buffer concentrate |
Heat Output* | c4000: 3050 BTU/hr, running mode; i1000SR: 2400 BTU/hr, running mode |
Sample Loading | RSH |